vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-019 Function-Group Ripped V-Belt > < C-017 Air Outlet Sensor Footwell Circuit

C-018 - Air Outlet Sensor Interior Circuit

Test

Work Order Description

Nominal Value

T001

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    B2_A14 Sensor - Outlet Air Ventilation
  • Ignition ON
  • Measure voltage between the following terminals:
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal A
    &
    Ground

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T002

Check: Component

  • Select the following Functional System on the diagnostic tester:
    ECC/SAC (Electronic Climate Control)
  • Diagnostic Tester Data List Parameter
    Interior Air Outlet Temperature

greater than 4.8 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T003

Check: Short to Voltage/Interruption of Signal Circuit

  • Ignition OFF
  • Connect fused jumper wire to:
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal A
    &
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal B
  • Ignition ON
  • Diagnostic Tester Data List Parameter
    Interior Air Outlet Temperature

less than 0.3 V

Diagnostic Tester Data List Parameter Current Value:
Yes: No:
T004

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    B2_A14 Sensor - Outlet Air Ventilation
  • Ignition ON
  • Measure voltage between the following terminals:
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal A
    &
    Ground

greater than 5.2 V

Voltage Measurement Current Value: V
Yes: No:


Result

Cause Of Fault

E001 Result: Defective Component
  • Defective component:
    B2_A14 Sensor - Outlet Air Ventilation
E002 Result: Interruption
  • Circuit interruption between:
    A1_A14 Control Unit - Climate Control
    Wiring harness connector (wiring harness side) terminal 23 (XC43)
    &
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal B

or

  • Defective component:
    A1_A14 Control Unit - Climate Control

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E003 Result: Defective Component
  • Defective component:
    A1_A14 Control Unit - Climate Control

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E004 Result: Short to Voltage
  • Short circuit to voltage between:
    A1_A14 Control Unit - Climate Control
    Wiring harness connector (wiring harness side) terminal 24 (XC43)
    &
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal A

or

  • Defective component:
    A1_A14 Control Unit - Climate Control

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E005 Result: Short to Ground/Interruption
  • Short circuit to ground/interruption of circuit between:
    A1_A14 Control Unit - Climate Control
    Wiring harness connector (wiring harness side) terminal 24 (XC43)
    &
    B2_A14 Sensor - Outlet Air Ventilation
    Wiring harness connector (wiring harness side) terminal A

or

  • Defective component:
    A1_A14 Control Unit - Climate Control

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-019 Function-Group Ripped V-Belt > < C-017 Air Outlet Sensor Footwell Circuit