Work Order Description

Nominal Value

T001

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • All consumers turned off
  • Disconnect wiring harness connector from:
    A165 Control Unit - Open & Start
    &
    Diagnostic tester
  • Ignition ON
  • Measure voltage between the following terminals:
    A165 Control Unit - Open & Start
    Wiring harness connector (wiring harness side) terminal 18
    &
    Ground

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T002

Check: Interruption of Voltage Supply Circuit

  • Measure voltage between the following terminals:
    A165 Control Unit - Open & Start
    Wiring harness connector (wiring harness side) terminal 20
    &
    Battery voltage

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • Remove electrical component from socket:
    FE16 Fuse
  • Ignition ON
  • Measure voltage between the following terminals:
    FE16 Fuse
    Input contact
    &
    Ground

greater than 11 V

Voltage Measurement Current Value: V
Yes: No:


Result

Cause Of Fault

E001 Result: Interruption
  • Circuit interruption between:
    A165 Control Unit - Open & Start
    Wiring harness connector (wiring harness side) terminal 7
    &
    X131 Rear Electronic Module
    Wiring harness connector (wiring harness side) terminal 31 (XR5)

or

  • Defective component:
    A165 Control Unit - Open & Start
    or
    X131 Rear Electronic Module

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

Note:

The replacement of the components must be done in the listed order.

The system must be checked for proper operation after every replacement.

E002 Result: Interruption
  • Circuit interruption between:
    A165 Control Unit - Open & Start
    Wiring harness connector (wiring harness side) terminal 20
    &
    Ground
E003 Result: Interruption
  • Circuit interruption between:
    X125 Underhood Electronic Module
    Socket Terminal 9 (XE2)
    &
    A165 Control Unit - Open & Start
    Wiring harness connector (wiring harness side) terminal 18
E004 Result: Interruption
  • Circuit interruption between:
    FE16 Fuse
    Input contact
    &
    G1 Battery
    Terminal 30

or

  • Defective component:
    X125 Underhood Electronic Module

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.