vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

C-053 Fuse FE11 Circuit > < C-051 Fuse FE9 Circuit

C-052 - Fuse FE10 Circuit

Test

Work Order Description

Nominal Value

T001

Check: Short to Ground of Voltage Supply Circuit

  • Ignition OFF
  • Reconnect all disconnected components
  • All consumers turned off
  • Insert new fuse FE10 and then check the fuse for proper operation.

Test okay?

Yes: No:


Result

Cause Of Fault

E001 Result: System Overload
  • A temporary current overload in the system behind fuse FE10 has occurred

Note:

In case of a temporary current overload, the cause for the blow of the fuse may be located in a circuit behind the control unit/component.

These circuits should be checked additionally for short to ground.

E002 Result: Short to Ground
  • Short circuit to ground between:
    X125 Underhood Electronic Module
    Socket Terminal 52 (XE1)
    &
    Diagnostic link
    Wiring harness connector terminal 16 (X40)

or

  • Defective component:
    X125 Underhood Electronic Module

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-053 Fuse FE11 Circuit > < C-051 Fuse FE9 Circuit