Result
|
Cause Of Fault
|
E001
|
Result: Defective Component
|
- Defective component:
K11_X125 Relay - Radiator Fan or A84 Control Unit - Engine
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
Note:
The replacement of the components must be done in the listed order.
The system must be checked for proper operation after every replacement.
|
|
E002
|
Result: Interruption
|
- Circuit interruption between:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 46 (XC4) & X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 2 (XE3)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E003
|
Result: Short to Ground
|
- Short circuit to ground between:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 46 (XC4) & X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 2 (XE3)
or
- Defective component:
X125 Underhood Electronic Module
Important:
Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.
|
|
E004
|
Result: Defective Component
|
- Defective component:
X125 Underhood Electronic Module
Important: