Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
B176 Sensor - Rail Fuel Pressure
- Ignition ON
-
Trouble Code Update
|
Is the diagnostic trouble code P0651 with status PRESENT stored?
|
|
T002
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
B150 Sensor - Boost Pressure
- Ignition ON
-
Trouble Code Update
|
Is the diagnostic trouble code P0651 with status PRESENT stored?
|
|
T003
|
Check: Component
|
- Ignition OFF
- Disconnect wiring harness connector from:
B22 Sensor - Pedal Position
- Ignition ON
-
Trouble Code Update
|
Is the diagnostic trouble code P0651 with status PRESENT stored?
|
|
T004
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC11 ) Ignition ON
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 28 (XC11) & Ground
|
less than 0.3 V
|
|
|
T005
|
Check: Short to Ground of Voltage Supply Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 28 (XC11) & Ground
|
greater than 500 kOhm
|
|
|
T006
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC12 )
- Ignition ON
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 46 (XC12) & Ground
|
less than 0.3 V
|
|
|
T007
|
Check: Short to Ground of Voltage Supply Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 46 (XC12) & Ground
|
greater than 500 kOhm
|
|
|
T008
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Ignition ON
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 13 (XC11) & Ground
|
less than 0.3 V
|
|
|
T009
|
Check: Short to Ground of Voltage Supply Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 13 (XC11) & Ground
|
greater than 500 kOhm
|
|
|
T010
|
Check: Short to Ground of Voltage Supply Circuit
|
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module (Wiring Harness Connector XE2 )
- Measure resistance between the following terminals:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 17 (XE2) & Ground
|
greater than 500 kOhm
|
|
|
T011
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module (Wiring Harness Connector XE2 )
- Ignition ON
- Measure voltage between the following terminals:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 17 (XE2) & Ground
|
less than 0.3 V
|
|
|
T012
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC12 )
- Ignition ON
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 31 (XC12) & Ground
|
less than 0.3 V
|
|
|
T013
|
Check: Short to Voltage of Ground Circuit
|
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 8 (XC12) & Ground
|
less than 0.3 V
|
|
|
T014
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module (Wiring Harness Connector XE2 )
- Ignition ON
- Measure voltage between the following terminals:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 18 (XE2) & Ground
|
less than 0.3 V
|
|
|
T015
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
X125 Underhood Electronic Module (Wiring Harness Connector XE2 )
- Ignition ON
- Measure voltage between the following terminals:
X125 Underhood Electronic Module Wiring harness connector (wiring harness side) terminal 3 (XE2) & Ground
|
less than 0.3 V
|
|
|