Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Ground/Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B69 Air Mass Meter
- Ignition ON
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 2 & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Short to Voltage/Interruption of Ground Circuit
|
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 2 & B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 3
|
greater than 11 V
|
|
|
T003
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 4 & Ground
|
4.8 ... 5.2 V
|
|
|
T004
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 5 & Ground
|
less than 0.3 V
|
|
|
T005
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Remove electrical component from socket:
K12_X125 Relay - Radiator Fan
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC7 )
- Measure resistance between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 5 & Ground
|
greater than 500 kOhm
|
|
|
T006
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 5 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 6 (XC7)
|
less than 5 Ohm
|
|
|
T007
|
Check: Short to Voltage of Ground Circuit
|
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 3 & Ground
|
less than 0.3 V
|
|
|
T008
|
Check: Short to Voltage/Interruption of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A111 Throttle Valve - Positioner
- Ignition ON
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 2 & B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 3
- Disconnect each of the following components/control units consecutively from the wiring harness and repeat the measurement each time:
B39 Sensor - Temperature, Coolant B26 Sensor - Atmospheric Pressure B150 Sensor - Boost Pressure
|
less than 0.3 V
|
|
|
T009
|
Check: Short to Voltage of Ground Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
M3A Motor - Radiator Fan M3B Motor - Radiator Fan and A84 Control Unit - Engine (Wiring Harness Connector XC7 )
- Ignition ON
- Measure voltage between the following terminals:
B69 Air Mass Meter Wiring harness connector (wiring harness side) terminal 3 & Ground
|
less than 0.3 V
|
|
|