Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Short to Voltage/Ground of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B166 Sensor - Oxygen, Mixture Control, Heated
- Ignition ON
- Diagnostic Tester Data List Parameter
B1 Short Term Fuel Trim (Bank 1)
|
430 ... 470 mV
|
|
|
T002
|
Check: Interruption of Signal Circuit
|
- Measure voltage between the following terminals:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 4 & Ground
|
430 ... 470 mV
|
|
|
T003
|
Check: Component
|
- Measure voltage between the following terminals:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 3 & Ground
|
less than 0.3 V
|
|
|
T004
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Remove electrical component from socket:
K12_X125 Relay - Radiator Fan
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector (XC7) )
- Measure resistance between the following terminals:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 4 & Ground
|
greater than 500 kOhm
|
|
|
T005
|
Check: Circuit Interruption of Ground Circuit
|
- Measure resistance between the following terminals:
B166 Sensor - Oxygen, Mixture Control, Heated Wiring harness connector (wiring harness side) terminal 4 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 8 (XC7)
|
less than 5 Ohm
|
|
|
T006
|
Check: Mechanical Functionality
|
- Check mechanical functionality of the following components and all attached parts:
Exhaust system Intake system Injection valves Fuel pressure
|
Test okay?
|
|
T007
|
Check: Short to Voltage/Ground of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B166 Sensor - Oxygen, Mixture Control, Heated
- Ignition ON
- Diagnostic Tester Data List Parameter
B1 Short Term Fuel Trim (Bank 1)
|
less than 430 mV
|
|
|