Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A40 Ignition Coil - Direct Ignition
- Ignition ON
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 2 & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Circuit Interruption of Ground Circuit
|
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 2 & A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 1
|
greater than 11 V
|
|
|
T003
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine
- Ignition ON
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 3 & Ground
|
less than 0.3 V
|
|
|
T004
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 4 & Ground
|
less than 0.3 V
|
|
|
T005
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 5 & Ground
|
less than 0.3 V
|
|
|
T006
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 6 & Ground
|
less than 0.3 V
|
|
|
T007
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 6 & Ground
|
greater than 500 kOhm
|
|
|
T008
|
Check: Short to Ground of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 5 & Ground
|
greater than 500 kOhm
|
|
|
T009
|
Check: Short to Ground of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 4 & Ground
|
greater than 500 kOhm
|
|
|
T010
|
Check: Short to Ground of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 3 & Ground
|
greater than 500 kOhm
|
|
|
T011
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 3 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 47 (XC99)
|
less than 5 Ohm
|
|
|
T012
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 4 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 64 (XC99)
|
less than 5 Ohm
|
|
|
T013
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 5 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 63 (XC99)
|
less than 5 Ohm
|
|
|
T014
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A40 Ignition Coil - Direct Ignition Wiring harness connector (wiring harness side) terminal 6 & A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 48 (XC99)
|
less than 5 Ohm
|
|
|
T015
|
Check: Component
|
- Check the following component for proper operation:
Spark plugs Spark plug connectors
|
Test okay?
|
|