Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Remove electrical component from socket:
K3_X125 Relay - Terminal 15
- Disconnect wiring harness connector from:
Y18 Actuator - Recirculation
- Connect fused jumper wire to:
K3_X125 Relay - Terminal 15 Socket Terminal 87 & Battery voltage
- Measure voltage between the following terminals:
Y18 Actuator - Recirculation Wiring harness connector (wiring harness side) terminal 1 & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Short to Voltage of Voltage Supply Circuit
|
- Disconnect wiring harness connector from:
A84 Control Unit - Engine
- Ignition ON
- Measure voltage between the following terminals:
Y18 Actuator - Recirculation Wiring harness connector (wiring harness side) terminal 2 & Ground
|
less than 0.3 V
|
|
|
T003
|
Check: Component
|
- Ignition OFF
- Connect wiring harness connector to:
Y18 Actuator - Recirculation
- Ground the following terminal briefly several times:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 50 (XC99)
|
Clicking noise from following component:
Y18 Actuator - Recirculation
|
|
T004
|
Check: Mechanical Functionality
|
- Check mechanical functionality of the following components and all attached parts:
Y18 Actuator - Recirculation
|
Mechanical function check okay?
|
|