Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
B67 Sensor - Absolute Pressure, Intake Manifold
- Ignition ON
- Measure voltage between the following terminals:
B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 3
(Z 16 XE1) 1
& Ground
|
(Z 16 XEP)
4.8 ... 5.2 V
(Z 16 XE1)
4.8 ... 5.2 V
|
|
|
T002
|
Check: Short to Voltage/Interruption of Signal Circuit
|
- Measure voltage between the following terminals:
B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 1
(Z 16 XE1) 2
& B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 3
(Z 16 XE1) 1
|
(Z 16 XEP)
4.8 ... 5.2 V
(Z 16 XE1)
4.8 ... 5.2 V
|
|
|
T003
|
Check: Short to Voltage of Signal Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine
- Ignition ON
- Measure voltage between the following terminals:
B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 2
(Z 16 XE1) 3
& Ground
|
(Z 16 XEP)
less than 0.3 V
(Z 16 XE1)
less than 0.3 V
|
|
|
T004
|
Check: Short to Ground of Signal Circuit
|
- Ignition OFF
- Measure resistance between the following terminals:
B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 2
(Z 16 XE1) 3
& Ground
|
(Z 16 XEP)
greater than 500 kOhm
(Z 16 XE1)
greater than 500 kOhm
|
|
|
T005
|
Check: Interruption of Signal Circuit
|
- Measure resistance between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 26 (XC9) & B67 Sensor - Absolute Pressure, Intake Manifold Wiring harness connector (wiring harness side) terminal
(Z 16 XEP) 2
(Z 16 XE1) 3
|
(Z 16 XEP)
less than 5 Ohm
(Z 16 XE1)
less than 5 Ohm
|
|
|