Test
|
Work Order Description
|
Nominal Value
|
T001
|
Check: Interruption of Voltage Supply Circuit
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC10 )
- Connect fused jumper wire to:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 16 (XC10) & Ground
- Measure voltage between the following terminals:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 2, 14, 19 (XC10) & Ground
|
greater than 11 V
|
|
|
T002
|
Check: Interruption of Voltage Supply Circuit
|
- Remove all fused jumper wires
- Ignition OFF
- Connect wiring harness connector to:
A84 Control Unit - Engine (Wiring Harness Connector XC10 )
- Disconnect wiring harness connector from:
Y56 Solenoid Valve - Exhaust Gas Recirculation
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal E & Ground
|
greater than 11 V
|
|
|
T003
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Ignition OFF
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC9 )
- Connect test light to:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal E & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal A
- Connect fused jumper wire to:
- Ground the following terminal briefly several times:
A84 Control Unit - Engine Wiring harness connector (wiring harness side) terminal 21 (XC9)
|
Test light flashes?
|
|
T004
|
Check: Short to Voltage/Ground/Interruption of Voltage Supply
|
- Remove all fused jumper wires
- Remove test light
- Connect wiring harness connector to:
A84 Control Unit - Engine (Wiring Harness Connector XC9 )
- Ignition ON
- Measure voltage between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal D & Ground
|
4.8 ... 5.2 V
|
|
|
T005
|
Check: Interruption of Signal Circuit
|
- Measure voltage between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal D & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal C
|
4.8 ... 5.2 V
|
|
|
T006
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal B & Ground
|
4.8 ... 5.2 V
|
|
|
T007
|
Check: Component
|
- Ignition OFF
- Connect fused jumper wire to:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal C & Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal B
- Ignition ON
- Diagnostic Tester Data List Parameter
EGR Position Feedback (Exhaust Gas Recirculation)
|
less than 0.3 V
|
|
|
T008
|
Check: Short to Voltage of Signal Circuit
|
- Measure voltage between:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal B & Ground
|
greater than 5.2 V
|
|
|
T009
|
Check: Short to Ground of Signal Circuit
|
- Disconnect wiring harness connector from:
A84 Control Unit - Engine (Wiring Harness Connector XC9 )
- Measure resistance between the following terminals:
Y56 Solenoid Valve - Exhaust Gas Recirculation Wiring harness connector (wiring harness side) terminal C & Ground
|
greater than 500 kOhm
|
|
|