C-020 - Rail Pressure Sensor Circuit

Test

Work Order Description

Nominal Value

T001

Check: Interruption of Voltage Supply Circuit

  • Ignition OFF
  • Disconnect wiring harness connector from:
    B176 Sensor - Rail Fuel Pressure
  • Ignition ON
  • Measure voltage between:
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 3
    &
    Ground

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T002

Check: Short to Voltage/Interruption of Ground Circuit

  • Measure voltage between:
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 1
    &
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 3

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:
T003

Check: Short to Voltage/Ground/Interruption of Signal Circuit

  • Measure voltage between the following terminals:
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 2
    &
    Ground

4.8 ... 5.2 V

Voltage Measurement Current Value: V
Yes: No:


Result

Cause Of Fault

E001 Result: Defective Component
  • Defective component:
    B176 Sensor - Rail Fuel Pressure
    or
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

After replacing the following component the programming function for the replacement of the corresponding component has to be performed by using the diagnostic tester:

B176 Sensor - Rail Fuel Pressure

Note:

The replacement of the components must be done in the listed order.

The system must be checked for proper operation after every replacement.

E002 Result: Short to Voltage/Ground/Interruption
  • Short to voltage/ground/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 38 (XC19)
    &
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 2

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E003 Result: Short to Voltage/Interruption
  • Short circuit to voltage/interruption of circuit between:
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 6 (XC19)
    &
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 1

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.

E004 Result: Interruption
  • Circuit interruption between:
    B176 Sensor - Rail Fuel Pressure
    Wiring harness connector (wiring harness side) terminal 3
    &
    A84 Control Unit - Engine
    Wiring harness connector (wiring harness side) terminal 8 (XC19)

or

  • Defective component:
    A84 Control Unit - Engine

Important:

Reset the concerned control unit with the diagnostic tester before replacing it. In order to do that, call up the "RESET" function from the PROGRAMMING menu of the current system on the diagnostic tester.






C-021 Fuel Metering Solenoid Valve Circuit > < C-019 Throttle Valve Positioner Circuit