Replace intake pipe pressure sensor

  Remove

1.   Open bonnet
2.   Remove throttle valve module LUREF_1.gif
3.   Disconnect wiring harness plug, intake pipe pressure sensor (1)
4.   Detach intake pipe pressure sensor from intake manifold
•   Unscrew bolt (2)
Object Number: 10680199  Size: DEFAULT


  Install

5.   Attach intake pipe pressure sensor to intake manifold
•   Tighten bolt
6.   Connect intake pipe pressure sensor wiring harness plug
7.   Install throttle valve module LUREF_1.gif
8.   Close bonnet