Inspect Before checking the charge pressure, check that the entire intake system is in good condition.
Remove, Disconnect Disconnect pressure hose from intake manifold to pressure unit on distributor injector pump. |
|
Install, Connect Connect suitable piece of hose between pressure hose and connection to intake manifold. Connect pressure gauge from MKM-667.
Inspect Start engine and allow to race without load. Max. charge pressure: 0.68 bar at 5600 rpm.
Remove, Disconnect Disconnect gauge.
Install, Connect Connect pressure hose to intake manifold. |
|
|