Objective:
Checking operation of the Oxygen sensor.
Measurement:
Plot of signal voltage of Oxygen sensor.
Preparation:
Engine oil temperature greater than 80°C . Switch off the engine and
ignition.
Connections:
INPUT A
|
COM/TRIGGER
|
INPUT B
|
Connect the red measurement lead and ground lead to the plug
connector for the camshaft sensor according to the table below.
|
|
|
Engine
|
Red measurement lead
|
Black ground lead
|
Z18XE
|
Pin 2
|
Pin 4
|
Other engines
|
Pin 4
|
Pin 3
|
Procedure Tech 31:
1. |
Download Reference curve. |
2. |
Start the engine and allow it to idle. |
3. |
If either little or no voltage variation can be
detected, the engine speed must be slightly increased. |
Reference Curve:
Ageing of the Oxygen
sensor can affect signal frequency for particular measurements. The
frequency is thus reduced as the sensor becomes older.
|
|
Procedure Tech 32:
1. |
Download Setup file (the Tech 32 uses only Setup
files, no reference curves). |
2. |
Start engine and allow it to idle. |
3. |
If either little or no voltage variation can be
detected, the engine speed must be slightly increased. |
Setup File:
Reference Curve:
|
|
|