Field Remedy: 2729
Subject: |
Door Check Strap - Corrosion |
Models: |
Engines: |
Option: |
Corsa-D 2007... |
All |
|
Complaint: |
Corrosion on the upper surface of the
riveted bolt of the check strap |
Cause: |
Humidity / water may lead to corrosion on
the surface of the riveted bolt. |
Production: |
|
Remedy:
In case of customer complaint clean check strap, including riveted
bolt (Picture I, arrow) by use of a cloth with suitable cleaning
detergent until any dirt and grease residues are eliminated.
If required remove corrosion by use of sandpaper.
Afterwards the cleaned surface of the riveted bolt needs to be painted
with a suitable black paint.
Ensure sufficient paint thickness to avoid further
corrosion.
Apply grease to check strap where necessary.
Labour Times: TC: Hours:
U3 272 90 Rework Check Strap 90 SA
The costs for this repair will be covered during warranty and policy.
For policy please refer to the Policy Guideline (WebPG/Kuugel).
The regular Warranty Procedure will apply.
FunctionalGroup: |
A - Body |
Complaint Group: |
03 - Corrosion |
Trouble Code: |
20 |
|