· Coolant
temperature less than 30 °C / 86 °F
or
· Load
signal lower than 4.1 ms
The value varies depending on
the engine speed.
· Engine
speed higher than 600 rpm and lower than 5000 rpm
· The
control unit performs an internal knock sensor circuit test every 253
combustions. If this test is not passed, the trouble code is set (control
unit fault).
Replacement values:
See trouble code 16
|