Motronic M 2.8.1 Quick Check F0: DATA LIST
No.
TECH 1 Display
Conditions for Checking
Nominal Value
Trouble Codes
Terminal
05
INTAKE AIR TEMP.
Engine running at idle speed, operating temperature
10 to 80 °C /
50 to 176 °F
3.9 to 1.3 V
69, 71
44, 30