62
|
POWER
CONTROL
RELAY
VOLTAGE LOW
|
-
|
· Short
circuit to ground at Ter. 54, valve Ter. 40 or Ter. 41 is
always recognized
· Return
from Ter. 54, despite final stages being switched off and voltage
control relay not actuated, lower than 0.1 V
· When
switching on, trouble code 62 cannot be differentiated from trouble
codes 17, 18, 29, 32, 35, as the hardware lockout is active and the relay
cannot be actuated.
Effects:
· Solenoid
valves (brake band, 1 - 2 / 3 - 4 shifting, 2 -
3 shifting, torque converter clutch) and electrohydraulic pressure
regulator are switched off
· If
the fault is recognized, the following gears can still be shifted manually in
each driving stage (emergency program):
"Driving stage"
(gear) "D"(4), "3"(4), "2"(3), "1"(1)
Note:
If fault POWER CONTROL RELAY VOLTAGE LOW
is set and trouble codes 17, 18, 29, 32 and / or 35 has the
status TC NOT PRESENT, the fault
should first be searched for in the relevant solenoid valve
|