Table 1, Diagnostic Plug (XD) and Voltage Supply, Check > < F0:DATA LIST - TEST STEP 34 SELECTED MODE

Additional Fault Diagnosis

 

 

 

 

 

 

     (see Service Instructions)

 

 

 

 

 

No.

System Components

Conditions for Checking

Nominal Value

Trouble Code

Terminal

01

REVERSING LAMPS CIRCUIT

Ignition ON

Depress brake pedal

Selector lever in "P", "N", "D", "3", "2", "1"

 

 

Selector lever in "R"

 

Both reversing lamps OFF

Both reversing lamps ON

 -

-

Notes on trouble-shooting:

Nominal value:

Cause of fault:

(If nominal value is not attained)

 

·   If only one reversing lamp illuminates during the above check with the selector lever in "R", the circuit of that lamp must be checked

Both reversing lamps are OK

 

·   Replace defective lamp

 

·   Check position of selector lever and of selector lever position switch S118

Position OK

·   Carry out adjustment as specified in Service Instructions

·   Ignition OFF

·   Open plug connection X8

·   Using multimeter, measure voltage:

     from:    plug X8 (wiring harness side)

                  Ter. D

     to:         ground, Ter. 31

 

 

·   Ignition OFF

lower than 0.1 volts

 

·   Ignition ON

 

 

higher than 11.5 V

With ignition OFF voltage higher than 0.1 volts:

 

·   Short circuit to voltage

     from:    plug X8 (wiring harness side)

                  Ter. D

     to:         S1 ignition lock Ter. 15

·   S1 ignition lock defective

 

 

 

 

With ignition ON voltage lower than 11.5 volts:

 

·   F15 fuse/socket defective

·   Short circuit to ground or circuit interruption

     from:    plug X8 (wiring harness side)

                  Ter. D

     to:         fuse F26

·   Short circuit to ground or circuit interruption

     from:    fuse F15

     to:         S1 ignition lock Ter. 15

·   Check circuit S1 ignition lock

 

 

·   Bridge plug X8 (wiring harness side)

     Ter. D and F with electrically fused cable

 

 

·   Ignition OFF

Reversing lamps OFF

With ignition OFF, reversing lamps are ON:

 

·   Short circuit to voltage

     from:    plug X8 (wiring harness side)

                  Ter. F

     to:         E17 and E18 reversing lamps

 

 

·   Ignition ON

Reversing lamps ON

With ignition ON, reversing lamps are OFF:

 

·   Short circuit to ground or circuit interruption

     from:    plug X8 (wiring harness side)

                  Ter. F

     to:         E17 and E18 reversing lamps

·   With short circuit to ground check fuse F15

·   Short circuit to voltage or circuit interruption

     from:    E17 and E18 reversing lamps

     to:         ground, Ter. 31

·   Check lamp/socket E17 and E18 of reversing lamps

 

 

 

All checks OK

·   Check plug connection X8 of selector lever position switch S118

·   Replace selector lever position switch S118

 

 

 

 

Table 1, Diagnostic Plug (XD) and Voltage Supply, Check > < F0:DATA LIST - TEST STEP 34 SELECTED MODE