Remove selector lever position switch – see operation
"Selector Lever Position Switch, Remove and Install (except Y 25
DT)".
Lever out seal ring (1) with suitable screwdriver or sharp
tool.
Install
Coat new seal ring with installation grease, position and
carefully drive in up to system with suitable socket wrench
(2).
Attach selector lever position switch (5) to selector lever
shaft (4) and (3) fasten – do not tighten yet.
Install and adjust selector lever position switch – see
operation "Selector Lever Position Switch, Replace" and "Selector