Trouble Code Table - Trouble Code 56 SELECTOR SWITCH UNDEFINED STATE > < F0:DATA LIST - TEST STEP 14 SELECTOR TER. G

F0:DATA LIST

 

 

 

     9 plug of U13 solenoid valve casing

 

 

 

 

After 20 s, the transmission fluid temperature replacement value of 130 °C/266 °F is taken. For this reason, the following test must be carried out immediately, or the trouble codes must be erased in the meantime.

For diagnosis, the important factor is the voltage beside the transmission fluid temperature on the TECH 1 display

 

 

 

     from:    X9 plug of main housing

                  Ter. F (SWBL)

     to:      ground

 

 

The time specified above refers to the trouble code setting condition. After 20 s, the transmission fluid temperature replacement value of 130 °C/266 °F is taken.

For diagnosis, the important factor is the voltage beside the transmission fluid temperature on the TECH 1 display

 

 

 

     from:    X9 plug of main housing

                  Ter. F (SWBL)

     to:         X9 plug of main housing

                  Ter. E (BRGN)

 

 

 

No.

TECH 1 Display

Conditions for Checking

Nominal Value

Trouble Codes

Terminal

15

TRANSM.OIL TEMP.

Ignition ON

Drive vehicle for an extended period

 

70 to 120 °C/

158 to 248 °F

approx. 1 V

 

65, 66, 68

16, 22

 Notes on trouble-shooting:

Nominal value:

Cause of fault:

(If nominal value is not attained)

 

·   Disconnect wiring harness plug:

 

 

·   Ignition ON

- 40 °C/

·   Short circuit to ground

·   TECH 1 data list TRANSM.OIL TEMP.

- 40 °F    4.94 V

Trouble code 65 may be stored

 

 

If trouble code 65 has already been stored, the TECH 1 display reads:

130 °C/

266 °F    4.94 V

(See note)

 

 

     from:    K85 transmission control unit wiring harness plug

                  Ter. 22 (SWBL)

     to:         X9 plug of main housing

     Ter. F (SWBL)

·   Check wiring harness plug for K85 transmission control unit

·   K85 transmission control unit defective

Note:

 

 

·   Bridge wiring harness plug within 10 s

 

 

·   TECH 1 data list TRANSM.OIL TEMP.

170 °C/

·   Circuit interruption

 

338 °F    0.02 V

 

 

If trouble code 66 has already been stored, the TECH 1 display reads:

130 °C/

266 °F    0.02 V

(See note)

     from:    K85 transmission control unit wiring harness plug

                  Ter. 22 (SWBL)

     to:         X9 plug of main housing

                  Ter. F (SWBL)

·   Check wiring harness plug for K85 transmission control unit

·   K85 transmission control unit defective

Note:

 

 

·   Wait at least 20 s, plug bridged

 

 

·   TECH 1 data list TRANSM.OIL TEMP.

130 °C/

266 °F    0.02 V

trouble code 66 is set at the same time,

status:                  PRESENT

 

 

·   K85 transmission control unit defective

·   Using multimeter, measure voltage

     from:    X9 plug of main housing

                  Ter. E (BRGN)

     to:      ground

lower than 0.1 V

·   Short circuit to voltage

     from:    K85 transmission control unit wiring harness plug

                  Ter. 16 (BRGN)

     to:         X9 plug of main housing

                  Ter. E (BRGN)

 

 

·   Bridge wiring harness plug

 

 

·   TECH 1 data list TRANSM.OIL TEMP.

 

 

Note:

For diagnosis, the important factor is the voltage beside the transmission fluid temperature on the TECH 1 display

 

130 °C/

266 °F    0.02 V

Trouble code 66 must be set

status:   PRESENT

 

·   Circuit interruption

     from:    K85 transmission control unit wiring harness plug

                  Ter. 16 (BRGN)

     to:         X9 plug of main housing

                  Ter. E (BRGN)

 

 

 

If nominal values are attained

·   U13.4 transmission fluid temperature sensor defective

 

 

 

 