vauxhall Workshop Repair Guides

Vauxhall Workshop Service and Repair Manuals

Solenoid Valve, Pressure Regulator > < Solenoid Valve, 1-2 / 3-4 Shift

Solenoid Valve, 2 - 3 Shift

 

The design of the 2 - 3 shift solenoid valve also corresponds to that of the converter clutch solenoid valve. It is located in the main housing.

 

In contrast to the converter clutch and 1 - 2 / 3 - 4 shift solenoid valves, the 2 - 3 shift solenoid valve is open under normal conditions.

 

he 2 - 3 and 1 - 2 / 3 4 shift solenoid valves together regulate) the "open / closed" combinations for all gears. They also receive their shift pulses from the control unit.

 

·    Service

 

Each solenoid valve can be replaced individually, disassembly is however not possible.

 

Solenoid Valve, Pressure Regulator > < Solenoid Valve, 1-2 / 3-4 Shift