Omega B
Solenoid Valve, 2 - 3 Shift
The design of the 2 - 3 shift solenoid valve also corresponds to that of the converter clutch solenoid valve. It is located in the main housing.
In contrast to the converter clutch and 1 - 2 / 3 - 4 shift solenoid valves, the 2 - 3 shift solenoid valve is open under normal conditions.
he 2 - 3 and 1 - 2 / 3 4 shift solenoid valves together regulate) the "open / closed" combinations for all gears. They also receive their shift pulses from the control unit.
· Service
Each solenoid valve can be replaced individually, disassembly is however not possible.
|