B-13, Programming the window winders |
Test |
Work order description |
Nominal value |
T01 |
Functional check/programming |
|
|
• After replacement, adjustment work or functional check of window winder and/or reconnection of the battery, the window winder electronics must be reprogrammed. |
Programming executable |
|
After switching on the ignition, the window is completely closed by constant actuation of the corresponding switch. After closing the window, the switch must continue to be actuated for 5 seconds. |
|
|
After this process, the window winder should be programmed (automatic closing or opening to final stop is possible, pinch guard is activated). |
|
|
Yes: E02 |
No: E01 |
B-13, Programming of window winders |
Result |
Cause of fault |
E01 |
• Replace corresponding window winder motor |
E02 |
• No fault determinable |
C-01, Check left window winder switch assembly S37
|