Auxiliary heating mode
- Make
- Volkswagen
- Model
- Caddy Mk4
- Year
- 2015–2020
- Section
- Regulation of auxiliary/supplementary heater › Auxiliary heating mode
Auxiliary heating mode
Press instant heating button (1).

Press instant heating button (1).

Press instant heating button (1).

Once the coolant temperature has reached 82°C, the control unit switches to the energy-saving part load mode. If the coolant temperature continues to rise above 88°C, the control unit switches to the controlled waiting period. If the coolant temperature does not drop below 70°C within 900 seconds during the controlled waiting period, the heater unit will start with the normal start procedure in full-load mode when the coolant temperature does drop below 65°C.
Parts & tools for this job For 2015 Volkswagen Caddy
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Caddy 2015 cabin filter
As an Amazon Associate we earn from qualifying purchases.