Switching off auxiliary/supplementary heater
- Make
- Volkswagen
- Model
- Caddy Mk4
- Year
- 2015–2020
- Section
- Regulation of auxiliary/supplementary heater › Switching off auxiliary/supplementary heater
Switching off auxiliary/supplementary heater
When switched off manually or after a maximum operating time of 60 minutes or the coolant reaches a temperature of 84°C, combustion is ended and the run-on mode begins. The circulation pump V55 and the combustion air blower V6, however, continue to run to cool down the auxiliary heater (run-on mode) and are switched off automatically.
Note
- The run-on period of the circulation pump V55 and the combustion air blower V6 depends on the operating mode in which the auxiliary heater was switched off.
The run-on period is 175 seconds when heater is switched off during full-load operation and 110 seconds for part-load operation.
Depending on the control unit software version, slight deviations in the specified run-on values are possible.
Parts & tools for this job For 2015 Volkswagen Caddy
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Caddy 2015 cabin filter