Workshop Manuals Factory service & repair Volkswagen
01 Manual Gearbox, 2004»02 Manual Gearbox, 2007»03 Brakes, 2004»04 Wheels and Tyres Guide05 Bodywork, 2004»06 Bodywork, 2007»07 Electrical system, 2004»08 Running Gear, 2004»09 Heating, 2004»10 Electrical system, 2006»11 Heating, 2006»12 4 Cylinder Fuel injection Engine Mechanics (1.6L & 1.4L), 2004»13 4 Cylinder Carburettor Engine Mechanics (1.4L), 2004»14 Electrical system, 2007»15 4 Cylinder Carburettor Engine Mechanics (1.4L), 2007»16 4 Cylinder Fuel injection Engine Mechanics (1.8L, 1.6L & 1.4L), 2007»17 4 Cylinder Fuel injection Engine Mechanics (1.6L & 1.4L), 2008»18 Electrical system, 2008»19 Bodywork, 2009»20 Electrical system, 2009»
Volkswagen Citi Golf South Africa (1984-2009)01 · Manual Gearbox, 2004»
01 · Transmission

Calculating maximum permissible working dimension

Make
Volkswagen
Model
Citi Golf South Africa
Year
1984–2009
Section
Final drive, Differential › Calculating maximum permissible working dimension
Manual Gearbox, 2004»Calculating maximum permissible working dimension

Calculating maximum permissible working dimension

Insert valve and press firmly against seat.

Note

  • If the valves is to be renewed as part of a repair, use a new valve for the calculation.

Measure distance (a) between end of valve stem and upper edge of cylinder head.

V15-0640

Calculate max. permissible reworking dimension from measured distance (a) and minimum dimension.

Minimum dimension:
Inlet valve33.80 mm
Exhaust valve34.10 mm

Measured distance minus minimum dimension.

Example:

Measured distance (a)35.10mm
–Minimum dimension34.40mm
=Max. perm. rework dimension0.70mm

Note

  • If the measured distance (a) is smaller than the minimum dimension repeat measuring process with new valves and if necessary use shorter valves.

Parts & tools for this job For 1984 Volkswagen Citi Golf

As an Amazon Associate we earn from qualifying purchases.