Removing and installing condenser
- Make
- Volkswagen
- Model
- Crafter Mk1
- Year
- 2006–2016
- Section
- Refrigerant circuit › Removing and installing condenser
Removing and installing condenser
Evacuate refrigerant circuit using e.g. air conditioner service station VAS 6007A (or later model). Then - and only then - open refrigerant circuit.
Observe notes → Chapter.
Remove radiator fan housing → Chapter.
Warning Danger from refrigerant escaping under pressure!
Freezing of skin and other body parts.
Evacuate the refrigerant and then open the refrigerant circuit immediately.If more than 10 minutes have elapsed since evacuation and the coolant circuit has not been opened, evacuate the refrigerant again. Pressure builds up in the coolant circuit as a result of secondary evaporation.
Disconnect refrigerant lines on condenser. (Torque setting of nuts on block connection is 7.5 Nm.)
Remove high pressure sender G65Chapter.
Remove dryer cartridge → Chapter.
Remove bolt (arrow).

Disengage retaining clips for radiator and push in direction of engine compartment.

Disengage retaining clips for condenser and push upwards out of retainers.

Remove condenser.
Install in reverse order.
Always renew O-rings.
Parts & tools for this job For 2006 Volkswagen Crafter
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Crafter 2006 cabin filter