Removing and installing dryer cartridge
Note
- The dryer cartridge need not be renewed each time the refrigerant circuit is opened.
- Notes on repairing vehicles with an air conditioning system and on handling refrigerant can be found in the ELSA system.
- Select internet in ELSA. Air conditioning system - with refrigerant R134a VW can be found in the technical information.
Evacuate refrigerant circuit using e.g. air conditioner service station VAS 6007A (or later model). Then - and only then - open refrigerant circuit.
Observe notes → Chapter.
Remove radiator fan housing → Chapter.
Warning Danger from refrigerant escaping under pressure!
Freezing of skin and other body parts.
Evacuate the refrigerant and then open the refrigerant circuit immediately.If more than 10 minutes have elapsed since evacuation and the coolant circuit has not been opened, evacuate the refrigerant again. Pressure builds up in the coolant circuit as a result of secondary evaporation.
Remove bolt (1).

Pull out dryer cartridge in (direction of arrow A).
Pull dryer cartridge in (direction of arrow B) off condenser.
Always renew O-rings of condenser.
During installation, ensure proper seating of condenser retaining device.