Eos (1F7) V6-3.2L (BUB) (2008)
-
From the engine compartment, unscrew bolts - 1 - for refrigerant lines - 2 -.
-
Disconnect refrigerant lines from expansion valve - 3 -.
NOTE:
-
Seal all open line connections.
-
To seal off all open connections on expansion valve, sealing caps from a replacement expansion valve can be used (preventing dirt and
moisture from entering the system).
-
Cover floor carpet in vehicle interior with leak-proof foil and absorbent paper.
NOTE: During removal, take note of the lengths and assignment of bolts for reinstallation
1
-
Bolt
-
4 Nm
2
-
Bolts
-
Qty. 2
-
4 Nm
3
-
Cable bracket
4
-
Heating and A/C Unit
-
Removing:
-
Disconnect condensation water hose from heating and A/C unit.