Workshop Manuals Factory service & repair Volkswagen
01 4 - Cyl. injection engine (1.6 l)02 Troubleshooting, Mechanical Transmission03 5 - Speed manual gearbox (0AP, 02T)04 5 - Speed automated transmission (ASG) 0C305 Brake systems06 Running gear, axles, steering07 Wheels and Tyres - Specifications08 Heating, air conditioning09 Electrical system10 Electrical: Communication11 General body repairs, interior12 General body repairs, exterior
Volkswagen Gol G5 with Voyage and Saveiro, Brazil (2008-2012)05 · Brake systems
05 · Brakes

Leak control

Make
Volkswagen
Model
Gol G5 with Voyage and Saveiro, Brazil
Year
2008–2012
Section
Vacuum system - Check › Leak control
Brake systemsLeak control

Leak control

Note

  • Atmospheric air pressure is 1013 mbar at sea level (N.N.)
  • Air pressure lowers as altitude increases (approx. 100 mbar/1000 m of altitude).
  • Local and climate variations also affect vacuum generation.
  • Cold engines, activated air conditioning systems, or simply an idling engine negatively affect vacuum generation.

Previously test all vacuum hoses for damages (e.g. cracks or “ruptures”) as well as proper fitting.

Connect the servo brake vacuum measurement device VAS 6721Chapter

Open closing valve (A) .

Close closing valves (B) and (C).

N47-10210

Operate the engine at service temperature (>60ºC); briefly press the gas pedal once (engine rotation greater than 2,000 rpm).

In normal circumstances (check indications), the generated vacuum must be between 600 and 950 mbar (depending on the engine).

Open closing valve (C) to evacuate the servo brake.

N47-10213

Stop the engine.

Read and register the indicated measurement.

Vacuum must lower by 400 mbar in 12 hours.

In case of greater vacuum drop, you must test the leakage point located in the region of the ...

Brake servoor Retention valve, vacuum hoses with connectors and intake manifold/vacuum pump.

In case of major leaks, vacuum drops abruptly within a few seconds.

Perform vacuum control in the servo brake region:

After generating vacuum, close the closing valve (A) , to test the servo brake vacuum system.

N47-10214

Check the vacuum in the retention valve area, vacuum hose with connectors and suction tube/vacuum pump:

After generating vacuum, close the closing valve (C), to check the vacuum system of the servo brake vacuum measurement device VAS 6721 until the suction tube or vacuum pump.

N47-10210

To facilitate disassembly of adaptor and hose connections, open the closing valve (B) .

Parts & tools for this job For 2008 Volkswagen Gol