Vacuum generation control
- Make
- Volkswagen
- Model
- Gol G5 with Voyage and Saveiro, Brazil
- Year
- 2008–2012
- Section
- Vacuum system - Check › Vacuum generation control
Vacuum generation control
Note
- Atmospheric air pressure is 1013 mbar at sea level (N.N.)
- Air pressure lowers as altitude increases (approx. 100 mbar/1000 m of altitude).
- Local and climate variations also affect vacuum generation.
- Cold engines, activated air conditioning systems, or simply an idling engine negatively affect vacuum generation.
Previously test all vacuum hoses for damages (e.g. cracks or “ruptures”) as well as proper fitting.
Connect the servo brake vacuum measurement device VAS 6721Chapter
Open closing valve (A) .
Close closing valves (B) and (C).

Operate the engine at service temperature (>60ºC); briefly press the gas pedal once (engine rotation greater than 2,000 rpm).
Read the indicated measurement.
In normal circumstances (check indications), the generated vacuum must be between 600 and 950 mbar (depending on the engine).
If such values are not reached, despite meeting all requirements (check indications), the vacuum system must initially be tested for leaks.
Comparatively, generate vacuum with the manual vacuum pump VAS 6213Chapter.
To facilitate disassembly of adaptor and hose connections, open the closing valve (B) .
Parts & tools for this job For 2008 Volkswagen Gol
- PARTBrake padsSearch: Volkswagen Gol 2008 brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid