volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Checking secondary air inlet valve > < Checking combi-valve
4-Cyl. injection engine (cross-flow cylinder head), Mechanics
Secondary air system
Checking secondary air pump motor

Special tools, workshop equipment, testers, measuring instruments and auxiliary items required

 
W00-0459
  • ◆ V.A.G 1551 Fault reader

Note:

The vehicle system tester V.A.G 1552 can be used instead of the fault reader V.A.G 1551, however a print-out is not possible.

 
W00-0047
  • ◆ V.A.G 1551/3 Cable

Check conditions

 
N26-0319
  • ● → Fuse for secondary air pump relay (J299) -arrow- near battery OK.
  • ● The suction hose for secondary air pump is not blocked or kinked

Test sequence

  • ‒ Detach the pressure hose from the secondary air pump motor.
  • ‒ Activate the secondary air pump relay via the final control diagnosis.

=> Repair group 01; Final control diagnosis; Performing final control diagnosis

  • ‒ The secondary air pump motor must run at intervals, and air must exit the outlet connections.

If the motor runs, but no air exits:

  • ‒ Replace secondary air pump motor.

If the secondary air pump motor does not run at intervals:

  • ‒ Check activation of secondary air pump motor:

=> Repair group 01; Final control diagnosis; Performing final control diagnosis

Checking secondary air inlet valve > < Checking combi-valve