Golf Mk6
Note
|
1 - | Dash panel** |
q | Removing and installing → General body repairs, interior; Rep. gr.70 |
2 - | Sunlight penetration photosensor -G107- or sunlight penetration photosensor 2 -G134- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Function: sunlight penetration photosensor controls temperature flap and fresh air blower depending on light intensity |
q | Emergency running in event of failure: Climatronic control unit -J255- assumes fixed value |
q | Removing and installing → Chapter |
3 - | Centre vents |
q | Removing and installing → Chapter |
4 - | Right side vent |
5 - | Vent |
q | Removing and installing → Chapter |
6 - | Right vent temperature sender -G151- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
7 - | Climatronic control unit -J255- |
q | The Climatronic control unit -J255- and the operating and display unit for Climatronic air conditioning system -E87- are a single component which cannot be dismantled. |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
q | Renewing: the basic setting and an adaptation („Compressor first run“) must be carried out in the Guided Fault Finding or in the Guided Functions with the vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
8 - | Control motor for fresh air and air recirculation flap and air flow flap -V425- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
q | Renewing: initiate basic setting using vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
9 - | Footwell vent on front passenger side |
q | Removing and installing → Chapter |
10 - | Fresh air blower -V2- with fresh air blower control unit -J126- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing fresh air blower -V2- → Chapter |
q | Removing and installing fresh air blower control unit -J126- → Chapter |
11 - | Connector |
12 - | Baffle plate for heater unit |
13 - | Connecting piece |
q | For air duct |
q | Must be removed for removal of → General body repairs, interior; Rep. gr.68 |
14 - | Dust and pollen filter |
q | With activated charcoal filter |
q | Removing and installing → Chapter |
15 - | Air duct for right rear footwell |
q | Removing and installing → Chapter |
16 - | Rear footwell air duct |
q | Removing and installing → Chapter |
17 - | Evaporator temperature sensor -G308- or evaporator output temperature sender -G263- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
Note
One of the two component designations appears depending on software. The functions are identical. |
q | Removing and installing → Chapter |
18 - | Right temperature flap control motor -V159- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
q | Renewing: initiate basic setting using vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
19 - | Auxiliary air heater element -Z35-** |
q | Checking → Chapter |
q | Removing and installing → Chapter |
20 - | Heat exchanger |
q | Removing and installing → Chapter |
21 - | Front air distribution flap control motor -V426- with potentiometer for front air distribution flap control motor -G642- |
q | Checking: vehicle diagnosis, testing and information system -VAS 5051B- (or later model) |
q | Removing and installing → Chapter |
q | Renewing: initiate basic setting using vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
22 - | Footwell vent on driver side |
q | Removing and installing → Chapter |
23 - | Left temperature flap control motor -V158- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
q | Renewing: initiate basic setting using vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
24 - | Footwell vent temperature sender -G261- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing → Chapter |
25 - | Defroster flap control motor -V107- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |
q | Renewing: initiate basic setting using vehicle diagnosis, testing and information system -VAS 5051B- (or later model) → Chapter. |
26 - | Heater and air conditioning unit -VX1- |
q | Removing and installing → Chapter |
q | Dismantling and assembling → Chapter |
27 - | Right footwell vent temperature sender -G262- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing → Chapter |
28 - | Side vent |
29 - | Vent temperature sender -G150- |
q | Checking: Vehicle diagnosis, testing and information system -VAS 5051B- (or later model). |
q | Removing and installing → Chapter |