| Screw adapter -A- in to stop. |
–
| Engage angle piece of filling device for Haldex coupling 2 -VAS 6291--B- with adapter -A-. |
–
| Using filling device for Haldex coupling 2 -VAS 6291-, add enough oil so that it runs out between the adapter of the filling device and the final drive housing. |
–
| Remove filling device and adapter; excess oil may still run out. |
The oil level is correct when the Haldex coupling is filled to the lower edge of the filler hole. |
|
|
|