volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Assembly overview - charge air system > < Charge air system
Fitting hose connections with plug-in connectors
Fitting hose connections with plug-in connectors
  Caution
The seal in the plug-in connector can be damaged if the securing clip is in the locked position when fitting the connector. This can cause leakage. Observe installation instructions.
Removing
   
–  Release connector coupling by pulling retaining clip -arrow-; disconnect hose/pipe without additional tools.
Installing
–  On renewing oil seal in charge air hose groove; ensure that oil seal is seated completely in groove all around and is not twisted.
–  Coat sealing surface and oil seal with oil.
  N21-0184
–  Bring retaining clip to release position -1-.
–  Push charge air hose into coupling as far as stop.
–  Bring retaining clip to locking position -2- and then press charge air hose again.
–  By pulling on hose, check whether connector coupling seats correctly and is properly engaged.
  N21-10133

Assembly overview - charge air system > < Charge air system