Installing
- Make
- Volkswagen
- Model
- Golf Plus
- Year
- 2005–2014
- Section
- Air conditioning system with automatic regulation “Climatronic” › Installing
Heating, air conditioningInstalling
Installing
Install in reverse order. Note the following when doing this:
The control motor for fresh air and air recirculation flap and air flow flap V425 fits on the cable cam in one position only.

Note
- After installation, check operation of air flow flap and air recirculation flap.
- Initiate “basic setting” function using vehicle diagnostic testerChapter.
Parts & tools for this job For 2005 Volkswagen Golf
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Golf 2005 cabin filter