Note
- The air flow flap control motor V71 can be removed and installed without trouble only in the position “fresh air mode stop”. If the control motor should be stopped in a different position and cannot be moved electrically to the position “fresh air mode stop”, it can be pulled off and removed only with difficulty.
- The position of the fresh air and air recirculation flap must not be changed.
If necessary, switch on ignition, select “defrost” mode on the operating and display unit for front air conditioning system E87 (control motor is always set to “fresh air mode” in this position) and wait for control motor to reach “fresh air mode” end position.
Switch off ignition.
Remove glove compartment Rep. gr.68.

Unclip wiring harness from bracket (A).
Release catches (D) and (E) for retainer (A) on intake duct and remove retainer (A).
Mark connector to air recirculation flap control motor V113 (to avoid interchanging with connector to air flow flap control motor V71).
Remove recirculated air flap control motor V113Chapter.

Remove control motor (A) from intake duct.
Note
- The connection between the gears of the control motor and the air flow flap is designed so that the control motor can be removed without trouble only in the position “fresh air mode”.
- If the control motor is in a different position and can no longer move, the control motor must not simply be pulled off. First, the control motor must be released from its mounting points (B) with force. During this operation, ensure that gear (C) is not damaged.