Jetta Sedan L5-2.5L (BGP) (2005)
Defroster Flap Motor V107, Removing And Installing
Removing:
CAUTION:
-
Switch off all electrical consumers.
-
Switch ignition off and remove ignition key.
-
Remove drivers storage compartment
-
Remove left footwell air vent.
-
Remove bracket.
-
Disconnect electrical connection from motor - 2 -.
-
Remove screws - 1 -, remove motor - 2 - and unhook brace.
Installing:
Install in reverse order of removal, noting the following.
NOTE:
-
After installing, check motor/flap function.
-
Initiate "Basic Setting" function using Vehicle Diagnostic, Testing and Information System VAS 5051/5052 in operating mode "Guided Fault
Finding"
Air Flow Flap Motor V71, Removing and Installing
Air Flow Flap Motor V71, Removing And Installing
Removing:
CAUTION:
-
Switch off all electrical consumers.
-
Switch ignition off and remove ignition key.
-
Remove glove compartment
NOTE: Position of air flow flap must not be changed.