General body repairs, exteriorTest prerequisites
Test prerequisites
- Battery power OK
- All fuses OK as per current flow diagram
- Safety pin of tipper body inserted for tilting to one side
| Malfunction | Possible fault cause | Rectifying fault |
|---|
| Hydraulic pump motor V 160 does not run (no operating noise) | | |
| Defective wiring or connections | Check wiring and connectors using current flow diagram. |
| Button E 223 defective | Renew button E 223. |
| Relay J 432 defective | Renew relay J 432. |
| Hydraulic pump motor V 160 defective | Renew hydraulic pump motor V 160. |
| Malfunction | Possible fault cause | Rectifying fault |
|---|
| Tipper body does not tilt even though hydraulic pump motor V 160 is running (operating noise) | | |
| Tipper body is loaded beyond permissible level or blocked mechanically, thereby causing safety valve to intervene | Reduce load on tipper body or rectify block. |
| Leaks in hydraulic system (oil loss) | Seal leaks in system or renew defective component. |
| No hydraulic oil in reservoir or level too low | Replenish hydraulic oil. |
| Oil filter of hydraulic pump suction line is blocked | Renew or clean oil filter. |
| Leaking valve N 248, internal leak (no oil loss) | Renew valve N 248. |
| Hydraulic pump defective (mechanically) | Renew hydraulic pump. |
| Malfunction | Possible fault cause | Rectifying fault |
|---|
| Hydraulic pump V 160 does not switch off when maximum tilt angle is reached, causing safety cable to become damaged or stretched | | In addition to rectifying the fault, the safety cable and the cable mounting must always be checked and renewed as necessary. |
| Shutoff cable for limit switch F 239 not engaged, too long or torn | Engage shutoff cable, adjust to correct length or renew. |
| Limit switch installed too high, resulting in mechanical stop being reached before procedure is complete | Install limit switch F 239 in lower position. |
| Limit switch F 239 defective | Renew limit switch F 239. |
| Tipper body does not tilt to maximum tilt angle | | |
| Shutoff cable for limit switch F 239 too short or mechanically blocked | Renew shutoff cable, adjust to correct length and/or rectify block. |
| Hydraulic oil level in reservoir too low | Replenish hydraulic oil. |
| Leaks in hydraulic system (oil loss) | Seal leaks in system or renew defective component. |
| Leaking valve N 248, internal leak (no oil loss) | Renew valve N 248. |
| Malfunction | Possible fault cause | Rectifying fault |
|---|
| Tipper body lowers without button being pressed E 223 | | |
| Leaks in hydraulic system (oil loss) | Seal leaks in system or renew defective component. |
| Defective wiring or connections | Check wiring and connectors using current flow diagram. |
| Leaking valve N 248, internal leak (no oil loss) | Renew valve N 248. |
| Button E 223 defective | Renew button E 223. |
| Piston/s of multi-piston hydraulic cylinder defective | Renew multi-piston hydraulic cylinder. |
| Tipper body cannot be lowered | | |
| Tipper body propped or mechanically blocked | Remove prop or rectify block. |
| Defective wiring or connections | Check wiring and connectors using current flow diagram. |
| Button E 223 defective | Renew button E 223. |
| Valve N 248 defective | Renew valve N 248. |
| Malfunction | Possible fault cause | Rectifying fault |
|---|
| Warning lamp K 150 does not light up when tipper body is tilted | | |
| Tipper body is propped or mechanically blocked, resulting in hydraulic system not being charged with pressure | Remove prop or rectify block. |
| Defective wiring or connections | Check wiring and connectors using current flow diagram. |
| Warning lamp K 150 defective | Renew button E 223 with warning lamp K 150. |
| Pressure switch F 240 defective | Renew pressure switch F 240. |
| Warning lamp K 150 lights up when tipper body is not tilted | | |
| Defective wiring or connections | Check wiring and connectors using current flow diagram. |
| Pressure switch F 240 defective | Renew pressure switch F 240. |