Note
- Parts marked with an “*” can be repaired only in workshops with suitable equipment and specially trained mechanics because the refrigerant must be evacuated beforehand using, for example, the air conditioner service station VAS 6007A (or later model) → Chapter.

- Refrigerant hose*
From expansion valve to air conditioner compressor.
With damper - Refrigerant line*
- Refrigerant hose*
From expansion valve to receiver with dryer. - Evacuating and charging valve*
Releasing refrigerant into the environment is a punishable offence. - Expansion valve*
- Activated charcoal filter or dust and pollen filter
Removing and installing → Chapter - Water drain valve
Checking → Chapter - Radiator fan control unit J293
- Ambient temperature sensor G17
Function: ambient temperature sensor G17 controls temperature flap and fresh air blower, depending on temperature.
In event of failure:fresh air intake duct temperature sensor G89 takes over the function. If both sensors are defective, operation continues with an assumed value of +10° C. Air recirculation is not possible. The control and display unit for Climatronic air conditioning system E87 displays “--”.
Check with vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function.
Removing → Chapter - Receiver with dryer*
Removing ChapterNoteUnder certain conditions, it is not necessary to renew the receiver with dryer every time that the refrigerant circuit is opened. Information can be found in ELSA under “Air conditioning system with refrigerant R134a”Rep. Gr.00“Renewing components”. - Condenser*
Removing → Chapter - High-pressure safety valve*
Checking → Fig. - Refrigerant hose*
From air conditioner compressor to condenser. - Air conditioner compressor*
Engine code ARR:
Observe remarks on installation of air conditioner compressor → Chapter.NoteIf the air conditioner compressor has been exchanged because of internal damage, it is also necessary to purge the refrigerant circuit with refrigerant R134a. The procedure for purging can be found in the workshop manual “Air conditioning system with refrigerant R134a VW”Rep. Gr.00, Technical data, Clearing refrigerant circuit of contaminants.Observe running-in procedures for new air conditioner compressors → Chapter. - High-pressure sender G65
Removing → Chapter
Specified torque: 8 ± 1 Nm
Renew O-ring (note part number)
The high-pressure sender G65 can be removed without extracting the refrigerant from the refrigerant circuit.
The high pressure sensor G65 supplies information to radiator fan control unit J293 and engine control unit.Function:
Switches radiator fan V7 to next higher speed when pressure increases in refrigerant circuit.
The high-pressure sender G65 cannot be checked via the Climatronic self-diagnosis, but only via the engine control unit self-diagnosis.
Check with vehicle diagnosis, testing and information system VAS 5051A in “guided fault finding” function.
Switches off the air conditioner when the pressure is too high (for example, insufficient engine cooling).
Switches off the air conditioner when the pressure is too low (for example, loss of refrigerant). - Damper*
In refrigerant hose from expansion valve to air conditioner compressor.
Parts & tools for this job For 1998 Volkswagen Lupo
- PARTEngine gasket setSearch: Volkswagen Lupo 1998 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.