Installing
- Make
- Volkswagen
- Model
- Lupo 6X
- Year
- 1998–2005
- Section
- Climatronic air conditioning with automatic regulation › Installing
Heating, air conditioningInstalling
Installing
Attach air flow flap control motor V71 to shaft for fresh air and air recirculation flap (1).

Turn air flow flap control motor V71 in direction of (arrow A) and tighten bolts.
Clip in operating rod for air flow flap.
Push connector (1) onto air flow flap control motor V71(2).

After installing a new control motor, initiate “basic setting” using vehicle diagnosis, testing and information system VAS 5051 AChapter.
Parts & tools for this job For 1998 Volkswagen Lupo
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Lupo 1998 cabin filter