Heating, air conditioner
Self diagnosis of Climatronic
Read measured value block

Notes:

  • ◆ During the function "Read measuring value block" the Climatronic regulation is in operation.
  • ◆ There are 3 display groups each with 4 measuring values.
  • ◆ To read off the measuring values whilst driving a 2nd mechanic is required.
  • ‒ Connect fault reader V.A.G 1551 and input address word "08 Air conditioner/Heating electronics" and then press ⇒key, until "Select function XX" is shown in display .
 
→ Indicated on display (function selection):
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys -0- and -8- (08 initiates the "Read measured value block" function).
 
→ Indicated on display:
Rapid data transfer      Q
08 - Read measured value block
  • ‒ Confirm entry with the Q key.
 
→ Indicated on display:
Read measuring value block
Input display group number XX

Table of selectable display group numbers

Display group number

Display zone

Designation

01

1


2


3

4

Measured value of the ambient temperature sensor -G17-
Measured value of fresh air duct temperature sensor -G89-
Measured value of dash panel temperature sensor -G56-
Vehicles up to 07.95:
Measured value of coolant temperature sender -G62-
Vehicles from 08.95:
Measured value of vent temperature sender -G152-

02
cont.

1

2


3
4

Speed signal from speedometer sender -G22-
Measured value of sunlight penetration photo sensor -G107-
No display
Supply voltage (Term.15)

03

1
2

3

4

No display
Position of air conditioner pressure switch -F129-
A/C readiness/engine start recognized
Kick-down switch

 
→ Indicated on display:
(Specifications => Test table)
Read measured value block     1     ⇒
1     2     3     4

Notes:

  • ◆ Decoding the figures in the individual display zones => Test table Page 01-35 .
  • ◆ With the printer switched on the information on the display will be printed-out.
  • ◆ If the specifications are attained in all display zones:
  • ‒ Press ⇒key.
 
→ Indicated on display (function selection):
Rapid data transfer     HELP
Select function XX

Note:

After completing the "Read measured value block" function interrogate fault memory => Page 01-8

Test table

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

01

1

Measured value for ambient temperature sensor -G17-

Displayed figure corresponds to the ambient air temperature of temperature sensor


... °C

- Check wiring and connections according to current flow diagram
Replace -G17-

2

Measured value of fresh air intake channel temperature sensor -G89-

Displayed figure corresponds to the ambient air temperature of temperature sensor


... °C

- Check wiring and connections according to current flow diagram
Replace -G89-

3

Measured value of dash panel temperature sensor -G56-

Displayed figure corresponds to the ambient air temperature of temperature sensor


... °C

- Check wiring and connections according to current flow diagram
Replace -G56-

4

Vehicles up to 07.95: Measured value of coolant temperature sender -G62-
Vehicles from 08.95: Measured value of air vent temperature sender -G152-

Displayed figure corresponds to the temperature of the coolant temperature sender
Displayed figure corresponds to the ambient temperature of the air vent temperature sender


... °C

- Check wiring and connections according to current flow diagram
Replace -G62- or -G152-

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

02

1

Speed signal from speedometer sender -G22-

Displayed value corresponds to road speed


... km/h

- Check wiring and connections according to current flow diagram
Replace -G22- (only when the speedometer -G21- also does not indicate road speed)

2

Measured value for photo sensor for sunlight penetration -G107-

The displayed value is dependent upon the light intensity


0..100%

- Check wiring and connections according to current flow diagram
Replace -G107-

Dark

0%

Bright

100%

4

Supply voltage (on Climatronic control unit, connection -T10a/3-)

Displayed value corresponds to battery voltage


..V

- Check wiring and connections according to current flow diagram
Check alternator =>Current flow diagrams, Electrical fault finding, Fitting locations

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

03

2

Switch position of air conditioner pressure switch -F129-

- Refrigerant circuit fault-free
Condenser cooling is sufficient (2 bar/32 bar switch part closed, 16 bar switch part open)

101)

"00" indicated on 1551:
2 bar/32 bar switch part open, 16 bar switch part open. The refrigerant circuit is empty and must be taken to a specialist workshop.










Cont.

- Refrigerant circuit fault-free
Radiator fan increased output stage has switched on (2 bar/32 bar switch part closed, 16 bar switch part closed).

111)

"01" indicated on 1551:
2 bar/32 bar switch part open, 16 bar switch part closed. Condenser cooling insufficient (soiled); if not the refrigerant circuit is over-charged and vehicle must be taken to specialist workshop.

1)     The left figure informs of switch part 2 bar/ 32 bar switch position, the right figure informs of switch part 16 bar switch position (1 = closed, 0 = open).

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

03

2

"-0" indicated on 1551:
Checking the 2 bar/32 bar switch part is not possible at the moment, because the temperature switch is open. Condenser cooling is sufficient.







Cont.

"-1" indicated on 1551:
Checking the 2 bar/32 bar switch part is not possible at the moment, because the temperature switch is open. Radiator fan increased output stage has switched on.

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

03












Cont.

3

Air conditioner readiness1)/engine start recognized

- Climatronic switched on and engine started2):

Climatronic switched on and engine not started:

Climatronic switched off and engine not started:

Climatronic switched off and engine started:


113)


103)


003)


013)

- If the engine start is not recognized, check the wiring from terminal X to connector -T28a/21- on control unit.

1)     Air conditioner readiness will be recognized, if voltage is present at connector -T2n/1-

2)     The magnetic coupling -N25- will only be switched on when the engine start is recognized.

3)     The left figure informs of whether Climatronic is switched on (1 = Climatronic on, 0 = Climatronic off); The right figure informs of whether the engine is started (1 = Engine started, 0 = Engine not started).

Group number

Display zone

Designation

Test conditions

V.A.G 1551 display specification

Rectifying fault

03

4

Kick-down switch2)

- Kick-down switch operated (full throttle); vehicles with automatic gearbox:

Kick-down switch not operated; vehicles with automatic gearbox:

Vehicles with manual gearbox:


111)


011)


001)

"10" indicated on 1551:
Check wiring from automatic gearbox control unit -J217- to Climatronic control unit -J255-
If necessary renew control unit -J255-

1)     The left figure informs of the Kickdown switch position (1 = closed, 0 = open), the right figure informs on gearbox type (1 = automatic gearbox, 0 = Manual gearbox). If a gearbox, other than indicated, is installed then check wiring according to current flow diagram.

2)     Test is only possible during test drive.