Note:
After completing the "Read measured value block" function interrogate fault memory => Page 01-8
Test table
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
01
|
1
|
Measured value for ambient temperature sensor -G17-
|
Displayed figure corresponds to the ambient air temperature of temperature sensor
|
... °C
|
- Check wiring and connections according to current flow diagram
Replace -G17-
|
|
|
2
|
Measured value of fresh air intake channel temperature sensor -G89-
|
Displayed figure corresponds to the ambient air temperature of temperature sensor
|
... °C
|
- Check wiring and connections according to current flow diagram
Replace -G89-
|
|
|
3
|
Measured value of dash panel temperature sensor -G56-
|
Displayed figure corresponds to the ambient air temperature of temperature sensor
|
... °C
|
- Check wiring and connections according to current flow diagram
Replace -G56-
|
|
|
4
|
Vehicles up to 07.95: Measured value of coolant temperature sender -G62-
Vehicles from 08.95: Measured value of air vent temperature sender -G152-
|
Displayed figure corresponds to the temperature of the coolant temperature sender
Displayed figure corresponds to the ambient temperature of the air vent temperature sender
|
... °C
|
- Check wiring and connections according to current flow diagram
Replace -G62- or -G152-
|
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
02
|
1
|
Speed signal from speedometer sender -G22-
|
Displayed value corresponds to road speed
|
... km/h
|
- Check wiring and connections according to current flow diagram
Replace -G22- (only when the speedometer -G21- also does not indicate road speed)
|
|
|
2
|
Measured value for photo sensor for sunlight penetration -G107-
|
The displayed value is dependent upon the light intensity
|
0..100%
|
- Check wiring and connections according to current flow diagram
Replace -G107-
|
|
|
|
|
|
|
Dark
|
0%
|
|
|
|
|
|
|
|
Bright
|
100%
|
|
|
|
4
|
Supply voltage (on Climatronic control unit, connection -T10a/3-)
|
Displayed value corresponds to battery voltage
|
..V
|
- Check wiring and connections according to current flow diagram
Check alternator =>Current flow diagrams, Electrical fault finding, Fitting locations
|
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
03
|
2
|
Switch position of air conditioner pressure switch -F129-
|
- Refrigerant circuit fault-free
Condenser cooling is sufficient (2 bar/32 bar switch part closed, 16 bar switch part open)
|
101)
|
"00" indicated on 1551:
2 bar/32 bar switch part open, 16 bar switch part open. The refrigerant circuit is empty and must be taken to a specialist workshop.
|
|
Cont.
|
|
|
|
- Refrigerant circuit fault-free
Radiator fan increased output stage has switched on (2 bar/32 bar switch part closed, 16 bar switch part closed).
|
111)
|
"01" indicated on 1551:
2 bar/32 bar switch part open, 16 bar switch part closed. Condenser cooling insufficient (soiled); if not the refrigerant circuit is over-charged and vehicle must be taken to specialist workshop.
|
1)
The left figure informs of switch part 2 bar/ 32 bar switch position, the right figure informs of switch part 16 bar switch position (1 = closed, 0 = open).
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
03
|
2
|
|
|
|
|
"-0" indicated on 1551:
Checking the 2 bar/32 bar switch part is not possible at the moment, because the temperature switch is open. Condenser cooling is sufficient.
|
|
Cont.
|
|
|
|
|
|
"-1" indicated on 1551:
Checking the 2 bar/32 bar switch part is not possible at the moment, because the temperature switch is open. Radiator fan increased output stage has switched on.
|
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
03
Cont.
|
3
|
Air conditioner readiness1)/engine start recognized
|
- Climatronic switched on and engine started2):
Climatronic switched on and engine not started:
Climatronic switched off and engine not started:
Climatronic switched off and engine started:
|
113)
103)
003)
013)
|
- If the engine start is not recognized, check the wiring from terminal X to connector -T28a/21- on control unit.
|
1)
Air conditioner readiness will be recognized, if voltage is present at connector -T2n/1-
2)
The magnetic coupling -N25- will only be switched on when the engine start is recognized.
3)
The left figure informs of whether Climatronic is switched on (1 = Climatronic on, 0 = Climatronic off); The right figure informs of whether the engine is started (1 = Engine started, 0 = Engine not started).
|
|
|---|
|
Group number
|
Display zone
|
Designation
|
Test conditions
|
V.A.G 1551 display specification
|
Rectifying fault
|
|
03
|
4
|
Kick-down switch2)
|
- Kick-down switch operated (full throttle); vehicles with automatic gearbox:
Kick-down switch not operated; vehicles with automatic gearbox:
Vehicles with manual gearbox:
|
111)
011)
001)
|
|
"10" indicated on 1551:
Check wiring from automatic gearbox control unit -J217- to Climatronic control unit -J255-
If necessary renew control unit -J255-
|
1)
The left figure informs of the Kickdown switch position (1 = closed, 0 = open), the right figure informs on gearbox type (1 = automatic gearbox, 0 = Manual gearbox). If a gearbox, other than indicated, is installed then check wiring according to current flow diagram.
2)
Test is only possible during test drive.
|