volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heating, air conditioner|Heating > < Read measured value block
Heating, air conditioner
Self diagnosis of Climatronic
Erasing fault memory, ending output

Prerequisites:

  • ● Fault memory has been interrogated.

Erasing fault memory

- Press ⇒key.

 
→ Indicated on display (function selection):
Rapid data transfer     HELP
Select function XX
  • ‒ Press keys -0- and -5- (the function "Erase fault memory" is entered with 05).
 
→ Indicated on display:
Rapid data transfer     Q
05 Erase fault memory

- Confirm entry with the Q key.

 
→ Indicated on display:
Rapid data transfer     ⇒
Fault memory is erased!

-Press ⇒ key.

 
→ Indicated on display (function selection):
Rapid data transfer     HELP
Select function XX

Notes:

     
    → If this appears in the display, the test sequence is faulty.
    Warning!    
    Fault memory was not interrogated
  • ◆ Follow test sequence precisely: first interrogate fault memory, if necessary eliminate faults, then erase.
  • Ending output

    • ‒ Press keys -0- and -6- to end the output.
     
    → Indicated on display:
    Rapid data transfer     Q
    06 End output
    • ‒ Confirm entry with the Q key.
     
    → Indicated on display:
    Rapid data transfer     Help
    Enter address word XX
    • ‒ Switch off ignition.
    • ‒ Disconnect fault reader V.A.G 1551.

    Heating, air conditioner|Heating > < Read measured value block