volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Checking secondary air pump motor > < Removing and installing parts of the secondary air system
4-Cyl. Injection Engine, Mechanic
Secondary air system (Vehicles > 07.95)
Checking combi-valve and non-return valve
 
N26-0080

Special tools, testers and auxiliary items

  • ◆ Hand vacuum pump V.A.G 1390

Test sequence

  • ‒ → Pull vacuum hose -1- off secondary air inlet valve -2- (N112).
  • ‒ Connect hand vacuum pump V.A.G 1390 to vacuum hose -1-.
 
N26-0081
  • ‒ → Pull pressure hose -arrow- off non-return valve.

Note:

Do not use compressed air during the following check!

  • ‒ Connect aux. hose to non-return valve and blow into it.
         Valve must be closed.
  • ‒ Operate hand vacuum pump.
         Combi valve must open.