Line and component check with adapter cable (68-pin) -V.A.G 1598/18A- or adapter -V.A.G 1598/22- |
Note t
| Use the hand multimeter -V.A.G 1526C- or the multimeter -V.A.G 1715- and the voltage tester -V.A.G 1527B- for checking. |
t
| The specified values apply to an ambient temperature from 0 to + 40°C. |
t
| If the measured values deviate only slightly from the specified values, clean tester and measuring cable sockets and connectors and repeat check. Before renewing relevant components, check lines and connections and, particularly in case of specified values below 10∼Ω, repeat resistance measurement on component. |
t
| To connect testers to adapter cable (68-pin) -V.A.G 1598/18A-, use auxiliary cables from auxiliary measuring set -V.A.G 1594C-. |
t
| Contact numbers of connector and socket numbers of adapter cable (68-pin) -V.A.G 1598/18A- correspond. |
WARNING To prevent damage to the electronic components, select appropriate measuring range before connecting the measuring cables and observe the test requirements. |
|
|
|
|