| Measure resistance between change-over valve contacts. |
Specification: 25.0…45.0 Ω |
If the specification is not achieved: |
–
| Renew inlet connection together with variable intake manifold flap change-over valve -N239- → Chapter, Removing and installing inlet connection. |
–
| Read fault memory, if necessary, repair any faults and then clear fault memory → Chapter, Reading and clearing fault memory. |
If the specification is attained: |
|
|
|