Assembly overview - condenser
- Make
- Volkswagen
- Model
- Tiguan Mk1
- Year
- 2007–2016
- Section
- Refrigerant circuit › Assembly overview - condenser
Heating, air conditioningAssembly overview - condenser
Assembly overview - condenser

- Protective screen
Only on vehicles with heavy-duty equipment.
Only fitted on vehicles with 28° front end - Fastener
Qty. 8 - Condenser
Secured with 4 bolts to radiator - Sealing strip
Glue top sealing strip to 6th fin row from top of condenser before installing
Glue bottom sealing strip to 1st fin row from bottom of condenser before installing
Glue side sealing strips to outer edge of condenser before installing - Installation diagram for retaining clips
- Radiator
- Bolts
Qty. 4
5 ± 0.5 Nm - Receiver with dryerUnder certain conditions, it is not necessary to renew the receiver with dryer every time that the refrigerant circuit is opened. Refer to ELSA under Air conditioning system with refrigerant R134aRep. gr.00Renewing components.
Removing and installing → Chapter
Parts & tools for this job For 2007 Volkswagen Tiguan
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Volkswagen Tiguan 2007 cabin filter