Removing and installing expansion valve
The expansion valve atomises instreaming refrigerant. It regulates the flow so that the vapour, depending on heat transport, becomes a gas only upon reaching the outlet of the evaporator.
Special tools and workshop equipment requiredTorque wrench V.A.G 1331/

Note
- The refrigerant must be extracted beforehand, with the air conditioning service station.
- The previously used air conditioner service stations can still be used ⇒ Volkswagen Workshop Equipment catalogue.
- To prevent the intrusion of moisture, all components of the refrigerant circuit which have been opened must be sealed with suitable plugs.
Connecting pipe from charge air cooler must be removed on some vehicles Rep. gr.21.
Unscrew nuts (1) (9 ± 1.3 Nm).

Remove heat shield (2).
Place drip tray VAS 6208 beneath engine.
CAUTIONWhen the engine is warm, the cooling system is under pressure. Danger of scalding due to steam and hot coolant. There is a risk of injury to the skin and parts of the body due to scalding.Always wear safety gloves.Always wear safety goggles.Proceed as follows to release the pressure: cover the cap of the coolant expansion tank with a cloth, and open it carefully.Disconnect coolant pipe (2) to heat exchanger.

Unscrew nut (1) (9 ± 1.3 Nm) and bolt (3) (9 ± 1.3 Nm).
Pull coolant pipe slightly in direction of engine.
Extract refrigerant with air conditioning service station.
CAUTIONRisk of freezing injury caused by escaping pressurised refrigerant.There is a risk of injury to the skin and parts of the body due to freezing.Wear protective gloves.Wear eye protection.Extract refrigerant, and open the refrigerant circuit immediately afterwards.If more than 10 minutes have passed since the refrigerant was extracted, extract refrigerant again before opening the refrigerant circuit. Continued evaporation causes pressure to build up in the refrigerant circuit again.Unscrew bolts(1) and pull out refrigerant lines (2) from expansion valve.
Unscrew bolts (8) and remove expansion valve (4).

- Bolts
10 ± 1 Nm
Qty. 2 - Refrigerant lines on expansion valve
- O-ring
13.7 mm; 2.5 mm - Expansion valve
- O-ring
14 mm; 1.82 mm
Moisten with refrigerant machine oil when installing. - O-ring
10.8 mm; 1.82 mm
Moisten with refrigerant machine oil when installing. - O-ring
9.5 mm; 2.5 mm - Socket head combi-bolt
5 Nm
Install in reverse order.
- The expansion valve atomises incoming refrigerant and regulates the flow so that, depending on the heat transport, the vapour does not become a gas until it reaches the outlet of the evaporator.
Parts & tools for this job For 2007 Volkswagen Tiguan
- PARTEngine gasket setSearch: Volkswagen Tiguan 2007 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.