Refrigerant machine oil
- Make
- Volkswagen
- Model
- Tiguan Mk2
- Year
- 2016–2023
- Section
- Repair notes › Refrigerant machine oil
‹ Prev Important repair instructions concerning refrigerant and refrigerant oilNext › Handling pressure tanks
Air conditioning systems with R1234yf refrigerant - General informationRefrigerant machine oil
Refrigerant machine oil
CAUTIONRisk of chemical burn from atomised refrigerant oil. Eyes and other parts of the body could be injured.Wear protective gloves.Wear eye protection.Never inhale atomised refrigerant oil.- Refrigerant oil mixes with the refrigerant (about 10 - 40%, depending on compressor type and amount of refrigerant) and circulates constantly in the system, lubricating the moving parts.
- Special synthetic refrigerant oils, such as polyalkylene glycol (PAG) oil, are used in conjunction with R1234yf air conditioning systems with certain additives that have been adapted to the refrigerant. This is necessary owing to the fact that mineral oil, for example, does not mix with R1234yf. If the additives are not included, undesired reactions with the refrigerant or components of the refrigerant circuit can also ensue. In addition, the components of the R1234yf air conditioning system could be attacked if the mixture under pressure and at high temperatures flows through the refrigerant circuit or the lubricant film in the air conditioner compressor breaks down. The use of unapproved oils can lead to the of the air conditioning system, which is why only approved refrigerant oils may be used Electronic parts catalogue.
- Oil types for R1234yf refrigerant in motor vehicles: PAG oil with certain additives adapted to the R1234yf refrigerant (polyalkylene glycole with certain additives).
- The most important properties are high solubility in refrigerants, good lubrication characteristics, freedom from acid and very low water content. For this reason, only very specific oils may be used. For a list of approved refrigerant oils and fill capacities, see Electronic parts catalogue and Heating, air conditioning systemRep. gr.00Technical data (vehicle-specific workshop manual).
- The PAG oils suitable for refrigerant R1234yf are strongly hygroscopic and cannot always be mixed with other oils. Accordingly, only approved refrigerant oils should be used.
- Refrigerant oils age under the influence of moisture and acids. They become dark, viscous and aggressive towards metals. For this reason, keep containers with refrigerant oil closed to protect against the ingress of moisture. When containers are opened, seal them again straightaway.
- Because of its chemical properties, refrigerant oil must not be disposed of together with engine oil or gear oil. Refrigerant oil is to be disposed of as used oil of unknown origin (observe local regulations) VW / Audi-ServiceNet.
- For refrigerant circuits with R1234yf refrigerant, only oils approved for this refrigerant and the installed air conditioner compressor may be used Electronic parts catalogue and Heating, air conditioning systemRep. gr.00Technical data.
- Refrigerant oil that was developed for R134a refrigerant is not suitable for refrigerant circuits with R1234yf refrigerant (as specific additives are missing). Attention should therefore also be paid to the correct version Electronic parts catalogue and Heating, air conditioning systemRep. gr.00Technical data; Refrigerant oil.
- Refrigerant oil that was developed for R1234yf refrigerant may also be suitable for refrigerant circuits with R134a refrigerant. Heed noteElectronic parts catalogue and Heating, air conditioning systemRep. gr.00Technical data (vehicle-specific workshop manual).
Note
- Located on the refrigerant oil bottle are details about the period of use of the refrigerant oil contained within.
- This period can be ignored if the bottle remains sealed.
- Refrigerant oil can also be used after the period of use specified on the bottle provided the bottle was tightly sealed.
Note
- Do not store refrigerant oils exposed to the atmosphere as they are very hygroscopic (they readily absorb water).
- Always keep containers with refrigerant oil sealed. The same applies to the refrigerant circuit.
- Do not use ester oils (POE oils) as these can currently only be used in larger systems with different operating conditions (not for motor vehicle air conditioning systems).
‹ Prev Important repair instructions concerning refrigerant and refrigerant oilNext › Handling pressure tanks
Parts & tools for this job For 2016 Volkswagen Tiguan
- PARTOil filterSearch: Volkswagen Tiguan 2016 oil filter
- TOOLOil filter wrenchSearch: oil filter wrench
- FLUIDEngine oilSearch: Volkswagen Tiguan engine oil
As an Amazon Associate we earn from qualifying purchases.